Please enter a keyword to search
H19.2-100KW wind power, a typical HUMMER smart Wind turbine with a series of high-end technologies and refined material, is excellent in generation, stable in output and reliable in practice.
Efficient Generator
Hummer generator is one of the most advanced generators in the world. Made of refined permanent magnetic material, special copper alloy, aviation aluminum alloy and stainless steel, it is highly efficient in generating power. Due to its smallness, it is able to be placed inside the nose cone to reduce air resistance and increase efficiency.
Due to its advanced technologies, refined materials and unique design, H19.2-100kw wind turbinewind energy utilization factor is as high as 0.42 while generator efficiency is higher than 0.92.
Smart Control
H19.2-100kw wind turbine is controlled by a comprehensive smart system. Through our years of monitoring on wind turbine operation, we successfully develop an automatic control system for small and medium scaled wind turbines.
This smart system is able to automatically seek wind direction and constantly monitor generator working status, rotation speed, generator temperature, wind speed and direction etc. All data will be transmitted to control center.
When abnormal situation takes place ,our control center will instruct wind turbine to deflect from wind direction. After problem is released, wind turbine will turn to face wind direction again and resume generation.
H19.2-100kw wind turbine systems, both off grid and grid tied
data of the inveter
MODEL |
100KW |
INPUT VALUE of HUMMER (DC side) |
|
DC input voltage range |
300V-500V |
Consecutive overloading capacity |
110% |
Rated DC output Power |
100KW |
Personal Protection |
Ground |
OUTPUT VALUE of HUMMER (AC side) |
|
Rated power |
100KW |
AC Voltage Range(LINE -TO-NEUTRAL) |
180-250V AC/180-260V AC/180-270V AC |
AC Voltage Range(LINE -TO-LINE) |
340-420V AC |
AC Frequency |
47-51.5HZ/57-61.5HZ |
Power Factor |
>0.99 |
MAX Efficiency |
95% |
European Efficiency |
92% |
Internal Consumption during Operation |
<10W standby |
Protection |
Short circuit protection, over Heat protection, over load protection, safety protection |
Total Current Harmonic Distortion (THD) |
THD<3% |
Phase Shift |
0 |
Utility Monitor |
According to UL1741 |
Mechanical Specifications |
|
Size(W*H*D) |
1285 x1085 x 2085mm |
Net weight |
240kg |
Temperature |
-20°C~+40°C |
Characteristics |
|
Utility Disconnect |
Connect to NEC |
Cooling |
Wind cooling |
Display |
LED and LCD |
Communication |
RS485 |
EMC (Electromagnetic compatibility) |
EN50081, part1 |
EN50082, part2 |
|
Safety |
EN 50438 |
Grid interference |
EN61000-3-2 |
Main technical parameter:
Rated power(W) |
100000 |
Maximum output power (W) |
120000 |
Charging voltage (V) |
DC 460 |
Blade quantity |
3 |
Rotor blade material |
GRP |
Rotor blade diameter (ft.) |
20.8m |
Start-up wind speed (mph) |
5 (2.0m/s) |
Rated wind speed (mph) |
25 (11.0m/s) |
Rated rotating rate (r/min) |
100 |
Wind energy utilizing ratio (Cp) |
0.42 |
Generator output |
Frequency conversion AC |
Rated charging current (A) |
218 |
The maximum charging current (in a short time) (A) |
246 |
Output AC frequency (Hz) |
0~400 |
Generator efficiency |
>0.92 |
Free standing tower diameter (in.) |
Ø53.1*Ø20.9 (Φ1350×Φ530mm) |
Tower height (ft.) |
24m |
The weight of generator (lb) |
2646 (1200kg) |
Suggested Battery (Ah) |
800/1500 |